Triple Quadrupole LC-MS/MS Comparison
Triple quadrupole mass spectrometry (TQMS) is a versatile tool for quantitative analysis. Experience the excellent performance and robustness of Shimadzu’s LCMS-TQ instruments, which offer a choice of speed, sensitivity and resolution to meet the demands of high-throughput routine analysis and/or more specialized applications. 
Compare Shimadzu’s triple quadrupole LC-MS/MS systems below. 
Triple Quadrupole LC-MS/MS Comparison
| LCMS-8060RX | LCMS-8050RX | LCMS-8045RX | ||
|---|---|---|---|---|
| Features | The LCMS-8060RX builds on the exceptional sensitivity and UF capabilities of the LCMS-8060NX and adds even more robustness without compromising sensitivity. | Engineered to deliver excellent sensitivity the LCMS-8050RX further extends the performance of the LCMS-8050 to meet the ever-changing needs of any LC-MS/MS laboratory. | Designed for rugged, routine LC-MS/MS analysis with the optimal balance of cost, sensitivity and performance now enhanced with greater robustness and easier to use. | |
| Sensitivity (S/N) | ![]()  | 
			![]()  | 
			![]()  | 
		|
| Scan Speed | ![]()  | 
			![]()  | 
			![]()  | 
		|
| Ionization Unit Compatibility | ESI | |||
| APCI | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| DUIS*1) | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Heated-ESI | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Heated-ESI with IonFocus | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Micro-ESI | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Probe-ESI | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Measurement Mode | Q1 Scan/SIM | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		
| Q3 Scan/SIM | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| MRM | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Precursor ion scan | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Product ion scan | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Neutral loss scan | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Synchronized Survey Scan™*2) | 
			![]()  | 
			
			![]()  | 
			
			![]()  | 
		|
| Collision Cell | UFsweeper™*3) III | UFsweeper III | UFsweeper II | |
| QP guard *4) | 
			![]()  | 
			|||
| LCMS-8060RX | LCMS-8050RX | LCMS-8045RX | ||
- DUIS: The dual ion source continuously performs both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI).
 - Synchronized Survey Scan: Synchronized Survey Scan (SSS) automatically performs a product ion scanning whenever a pre-set survey scan threshold is exceeded.
 - UFsweeper: UFsweeper is a unique technology that delivers unparalleled efficiency and speed. UFsweeper accelerates ions out of the collision cell by forming a pseudo-potential surface.
 - QP guard: Reduces contamination of the quadrupole rod by applying voltage to the multi-pole and preventing unwanted ions from entering the quadrupole rod.
 